- Facility, Fit-Out & Interiors
Parking bay dimensions, aisle widths and turning circles: the layout that actually fits
A car's own turning circle is not what UAE parking codes actually regulate, which is why layouts fail on the aisle, not the bay. This verifies the real Dubai and Abu Dhabi figures.
- Facility, Fit-Out & Interiors
Dilapidations: budgeting for handing the space back
Handing back a UAE office means stripping it to shell and core, a cost rarely in the original fit-out budget. Here is what yield-up costs, what the law requires, and how to provision for it.
- Facility, Fit-Out & Interiors
Fit-out programme: the eight-week critical path
Eight weeks is achievable for a mid-size Dubai office fit-out, but only if Civil Defence and joinery start on day one. Here is the sequence that actually holds.
- Facility, Fit-Out & Interiors
Home cinema seating distance and screen size: the ratio that actually matters
Screen size in inches is the wrong starting point: SMPTE and THX both size a home cinema screen from the seat backwards. This article works the ratio and when a portable screen beats a fixed one.
- Facility, Fit-Out & Interiors
Large format tiles: layout, cuts and the waste penalty nobody budgets for
Large-format tile crosses a size threshold that changes substrate and handling rules, not just price. This piece works through the layout arithmetic and where the real cost lands in a fit-out budget.
- Facility, Fit-Out & Interiors
Meeting room display size and viewing distance: sizing for the back row, not the front
A meeting room display is sized from the smallest thing the back row must read, not the wall it fills. Most boardrooms use a different AVIXA formula than showrooms assume, and this article runs it.
- Facility, Fit-Out & Interiors
AC tonnage for a UAE villa: heat gain, glazing and orientation
A villa's AC tonnage isn't a function of floor area alone. Glazing area, glass SHGC, and which direction each facade faces change the actual heat gain enough to shift required tonnage meaningfully between two villas of identical size.
- Facility, Fit-Out & Interiors
Access control for a multi-tenant building
Access control in a multi-tenant building is two separate security problems layered on each other: controlling who enters the building, and controlling who can cross from one tenant's space into another's. Most gaps happen at that second boundary.
- Facility, Fit-Out & Interiors
Acoustic partitions: the spec that actually blocks a meeting room
A partition rated for "sound reduction" without a specific STC number is an unverifiable claim. Here's what the Sound Transmission Class scale actually means, and which rating a meeting room genuinely needs.
- Facility, Fit-Out & Interiors
Adding a server rack to an existing office board
A server rack's power draw isn't the only thing an existing office board has to absorb, the cooling load it creates and the redundancy it may need both change the sizing question. Treating it as "one more circuit" understates what's actually being added.
- Facility, Fit-Out & Interiors
Cable sizing and voltage drop over a 60 m run in Gulf temperatures
A cable sized correctly at 25°C can fail a voltage-drop check once Gulf ambient temperatures and a 60-metre run are both accounted for. The two effects compound, and sizing for one while ignoring the other is how circuits end up under-performing after installation.
- Facility, Fit-Out & Interiors
Camera count and coverage for a retail unit
"How many cameras do I need" doesn't have a single right answer, it has a right method: map the specific points a retail unit needs covered, then count cameras against that map rather than a rule of thumb.
- Facility, Fit-Out & Interiors
Circulation and accessibility in F&B layouts
A dining room that looks full on the floor plan often fails the moment real bodies, trays and wheelchairs move through it. Circulation and accessibility are two separate design constraints that both eat into usable seating, and treating them as one line item undersizes both.
- Facility, Fit-Out & Interiors
Colour temperature by space: why 4000K everywhere is a mistake
4000K is the "safe middle" a lot of fit-outs default to across every room. It's the wrong call for most of them: warm light supports relaxation, cooler light supports concentration, and a single Kelvin value can't do both jobs.
- Facility, Fit-Out & Interiors
Cooling a server room vs cooling an office: two different calculations
Office AC is sized for people and solar gain. Server room cooling is sized for continuous electronic heat load and runs to a tighter, ASHRAE-defined temperature band, 24/7, regardless of occupancy. Treating them as the same calculation undersizes one or oversizes the other.
- Facility, Fit-Out & Interiors
Covers per square metre by concept: QSR, casual, fine dining
How many covers a dining room should seat per square metre isn't one number, it changes by an order of magnitude between a QSR counter concept and a fine-dining room, and using the wrong benchmark for your concept produces a layout that's either too cramped or wastes rent.
- Facility, Fit-Out & Interiors
CRI for retail and F&B: when 90+ is worth the premium
Standard LEDs render colour at roughly CRI 80-83; high-CRI versions push to 95-99. The gap is invisible on a spec sheet and very visible on a plated meal or a rack of clothing, which is exactly where the premium is worth it.
- Facility, Fit-Out & Interiors
DEWA load application: what documents the connection request needs
A DEWA load connection application that's missing a single required document doesn't just get flagged, it stalls the entire fit-out programme behind it. Knowing what the application actually needs before submitting is the difference between a routine approval and a costly delay.
- Facility, Fit-Out & Interiors
District cooling vs own chillers: the UAE cost comparison
District cooling cuts 20-35% off the electricity a standalone chiller plant would use, and removes the 5-10% of total building cost a chiller plant otherwise consumes. The trade-off is a long-term supply contract you can't walk away from.
- Facility, Fit-Out & Interiors
Diversity factors: why total connected load is not your breaker size
Adding up every appliance's rated wattage and sizing the board to match is how boards get oversized by a wide margin. Nothing in a real building draws its full rated load simultaneously, and diversity factors exist specifically to correct for that.
- Facility, Fit-Out & Interiors
Drywall partition take-off: boards, studs and screws per linear metre
A drywall partition take-off is a per-linear-metre calculation, not a per-square-metre one, once you account for both faces, stud spacing, and the standard board size the calculation actually has to tile against.
- Facility, Fit-Out & Interiors
Emergency lighting and egress: the UAE civil defence minimum
Emergency lighting isn't sized like normal lighting: escape-route minimums, battery duration, and placement near fire alarm call points are all separate, specific requirements that a general lux calculation won't catch.
- Facility, Fit-Out & Interiors
Fire-rated partitions in the UAE: which walls need a rating
Not every internal wall needs a fire rating, but the ones that do are defined by their function in the building's fire-safety strategy, not by their location or how solid they look. Getting this wrong at fit-out stage is a civil defence sign-off risk, not a cosmetic one.
- Facility, Fit-Out & Interiors
Furniture, fixtures and equipment budget for 30 desks
An FF&E budget for a 30-desk office is not "30 times one desk price." Shared spaces, IT infrastructure, and soft-seating areas typically outweigh the individual workstation line, and pricing only the desks is how an FF&E budget understates the real number.